Input Voltage:
18~36VDC |
Input Current:
7A at 24VDC max. |
Inrush Current:
< 10A at 24VDC input from a cold start 25°C excluding EMI suppression capactiors |
Load Range:
With all other outputs within their accuracy ranges and all output at 60% rated load, the +5V output is between 4.95~5.05V. Max. load can not exceed 80W convenction cooling and 100W forced air cooling |
Ripple And Noise:
Peak to peak ripple and noise for +5V is < 50mV, and < 100mV for the other outputs at rated load, nominal line |
Line Regulation:
< +/-1% for each output at rated load and +/-10% of input voltage variables |
Load Regulation:
< +/-1% for +5V, and < +/-5% for -12V, +12V, -5V while changing measured output load from +/-40% to 60% rated load and keeping other outputs at 60% rated load |
Efficiency:
> 70% at DC24V and rated load |
Altitude:
> 10,000 feet |
Protection:
Built-in over voltage protection circuit. Trip point of crowbar circuit is between 5.7~7V. Hiccup mode against short circuit or over load conditions auto recovery when fault conditions are removed |
Temperature:
0~+50°C, can start up -20°C (operating); -40~+85°C (storage) |
Connectors:
DC Input: Terminal blocks DC Output: Molex 5273-12A |
Safety:
UL 1950 / CSA 22.2 No.234 / VDE EN60950 |
EMI:
FCC class B / EN55022 B |
EMS:
Level 3 of IEC-802, 803, 804 |
Dimensions:
15.24 x 8.38 x 3.8 cm with +/-0.8mm and +/-0.4mm tolerance between mounting holes |
|